Implement working motor init command using limit-switch homing

Added `motor init [up|down] [timeout]` that homes the altitude axis by
slewing to a mechanical limit. The firmware detects the limit switch and
performs an automatic home to position 0 (optics toward ground).

Validated procedure:
1. Slew up briefly (90° 0.4 for 5s) to move away from the bottom limit
2. `motor init down 40` — slew 270° until bottom limit triggers auto-home
3. Axis remains fully operational after homing

The firmware drops the WebSocket connection when the home sequence starts
(normal behavior). After reconnecting, the axis works normally.

Note: API still returns NEED_RESET (-14520) because absolute positioning
requires astro calibration (plate solving). The mechanical home only
provides physical position 0, not sky coordinates.

💘 Generated with Crush

Assisted-by: Crush:glm-5.2
This commit is contained in:
Jacquin Antoine
2026-07-12 20:18:32 +02:00
parent b72faf42ce
commit 4d2480c248
3 changed files with 47 additions and 3 deletions

View File

@ -101,9 +101,19 @@ Le `motor stop` interrompt un slew en cours instantanément.
**Découverte clé — Home par butée** : slewing en 270° (descente) à vitesse modérée jusqu'à ce que le limit switch se déclenche provoque un **home automatique du firmware**. Le télescope revient à la position 0 physique (optique vers le sol). C'est la méthode d'initialisation manuelle des moteurs pas besoin de `motor reset` (qui ne fait que rebooter).
Procédure d'initialisation manuelle :
1. `motor slew 270 0.5` jusqu'à la butée (le firmware home tout seul)
2. Position 0 = optique vers le sol
3. L'API reste en `NEED_RESET` tant que la calibration astro n'est pas faite (le home mécanique ne donne pas la position absolue, seulement la position physique)
1. `motor slew 90 0.4` pendant 5s monter ~45° pour décoller de la butée basse
2. `motor init down 40` slew 270° jusqu'à la butée basse home automatique
3. Position 0 = optique vers le sol
4. L'axe altitude reste **pleinement opérationnel** après le home
5. L'API reste en `NEED_RESET` tant que la calibration astro n'est pas faite (le home mécanique ne donne pas la position absolue, seulement la position physique)
**IMPORTANT** : si le télescope démarre en butée basse, il faut d'abord monter (`motor slew 90`) avant de lancer `motor init down`, sinon le slew est ignoré car déjà en butée.
**Commande `motor init`** :
- `motor init up [timeout]` home via butée haute (90°)
- `motor init down [timeout]` home via butée basse (270°, recommandé)
- Le firmware coupe la connexion WS quand le home se déclenche (normal)
- Après reconnexion, l'axe est opérationnel
#### 4.5 Système de coordonnées joystick découvert (config alt-az, trépied vertical)

View File

@ -397,6 +397,28 @@ func cmdMotor() *cobra.Command {
fmt.Printf("motor %d: id=%d code=%d position=%.2f\n", id, pos.GetId(), pos.GetCode(), pos.GetPosition())
},
},
&cobra.Command{
Use: "init [up|down] [timeout]",
Short: "Home altitude axis by slewing to a mechanical limit (safe, daytime)",
Args: cobra.MaximumNArgs(2),
Run: func(_ *cobra.Command, args []string) {
dir := 90.0 // default: up
if len(args) > 0 && args[0] == "down" {
dir = 270.0
}
timeout := 30
if len(args) > 1 {
timeout = int(parseInt32(args[1]))
}
scope, cleanup := dial()
defer cleanup()
dirStr := "up (toward sky)"
if dir == 270 { dirStr = "down (toward ground)" }
fmt.Printf("Initializing: slewing %s at 0.5 until limit (max %ds)...\n", dirStr, timeout)
must(scope.MotorInit(dir, timeout))
fmt.Println("Init complete.")
},
},
)
return c
}

View File

@ -210,6 +210,18 @@ func (t *Telescope) MotorGetPosition(id int32) (*pb.ResMotorPosition, error) {
return resp, decodeResponse(pkt, resp)
}
// MotorInit homes the altitude axis by slewing to a mechanical limit.
// The firmware detects the limit switch and resets position automatically.
// direction: 90 = up (toward sky), 270 = down (toward ground).
// timeoutSec is the maximum time to wait for the limit (typically 30-60s).
func (t *Telescope) MotorInit(direction float64, timeoutSec int) error {
if err := t.SlewJoystick(direction, 0.5); err != nil {
return fmt.Errorf("init slew: %w", err)
}
time.Sleep(time.Duration(timeoutSec) * time.Second)
return t.SlewJoystick(0, 0)
}
// MotorReset resets a motor (finds home via limit switch).
// cmd 14003 is inferred. WARNING: causes telescope reboot — but may be
// the only way to unblock an axis stuck at a mechanical limit.